* True On-Line UPS Systems
(1.0 KVA to 200.0 KVA) Isolation Technology, ETDC Tested
  * True On-Line UPS Systems
(1.0 KVA to 3.0 KVA) - High Frequency Technology
Images   Images

True On-Line Double Conversion Technology with Galvanic Isolation
When main power is present, the UPS converts the input AC voltage to DC to charge the battery and to supply the inverter with energy. The inverter generates a sinewave AC voltage which is permanently available at the output of the UPS through an isolating transformer. If a problem occurs with the main power supply, the battery delivers the necessary power to the inverter, additional bypass system which is integrated into the UPS guarantees the highest possible level or reliability. In cases of overload or short circuit, the bypass system automatically connects the main power input directly through to the electrical load.

True On-Line UPS Systems - Standard Specification

Parameters
ISOLATION TECHNOLOGY
HIGH FREQUENCY
(W/O ISOLATION)
Single Phase
Three Phase
Single Phase
Capacity 1.0 KVA - 50.0 KVA 10.0 KVA - 200.0 KVA 1.0 KVA - 3.0 KVA
Input Voltage Nominal 230 Vac 400 Vac 230 Vac
Input Voltage Range 170 - 270 Vac 295 - 465 Vac 160 - 270 Vac
Input Frequency Range 47 - 53 Hz 47 - 53 Hz 47 - 53 Hz
Input Power Factor 0.95 with active filtering 0.95 with active filtering > 0.95 with active filtering
Output Voltage Nominal 230 Vac 400 Vac 230 Vac
Output Voltage Regulation ± 1% ± 1% ± 1%
Output Frequency Nominal 50 Hz 50 Hz 50 Hz
Output Frequency Range ± 0.05% ± 0.05% ± 0.05%
Output Waveform Pure sinewave Pure sinewave Pure sinewave
THD < 3% (Linear) < 2% (Linear) <2% (Linear)
Load Power Factor 0.8pf 0.8pf 0.8pf
Load Power Rating in KWatts 0.8 Times KVA Rating 0.8 Times KVA Rating 0.8 Times KVA Rating
Transient Response ± 5V / 1Cy. ± 5V / 1Cy. ± 5V / 1Cy.
Efficiency > 90% > 90% > 90%
Rectifier Charger CC-CV Fully automatic float cum boost charger CC-CV Fully automatic float cum boost charger CC-CV Fully automatic float cum boost charger
Inverter Adaptive sine-weighted pulse width modulated (IGBT) Adaptive sine-weighted pulse width modulated (IGBT) Adaptive sine-weighted pulse width modulated (IGBT)
Protections Under / Over Voltage, Overload / Short Ckt. Under / Over Voltage, Overload / Short Ckt. Under / Over Voltage, Overload / Short Ckt.
Indications Mains On, Inv. On, Btty. Low, Btty. On Trip Mains On, Inv. On, Btty. Low, Btty. On Trip Mains On, Inv. On, Btty. Low, Btty. On Trip
Metering Analog / Digital for Input and Output Analog / Digital for Input and Output Analog / Digital for Input and Output
Options Static bypass Software Interface Static bypass Software Interface Static bypass Software Interface
       